What is a Cross Bore – and How Does GPRS Help Prevent Them?

The underground infrastructure of our cities is a complex network of pipelines and cables, essential for providing utilities like gas, water, and telecommunications.

As urban areas expand and the demand for these services increases, the challenge of installing and maintaining this subsurface infrastructure grows. One significant concern that has emerged and grown with the advent of trenchless technology is the issue of cross bores.

 A cross bored sewer pipe.

What are Cross Bores?

A cross bore is a situation where a new utility line, typically installed using trenchless methods such as directional boring, inadvertently intersects and potentially breaches an existing underground utility, most commonly a sewer line. This unintended intersection can create a pathway for gas or other hazardous materials to leak into the sewer system, posing significant risks to public safety and the environment.

A directional boring drill bit penetrating the ground.

How are Cross Bores Created?

Cross bores are primarily a byproduct of trenchless technology, a method of installing underground utilities without open trench excavation. Techniques like directional boring allow for the installation of new pipelines with minimal surface disruption, making it an attractive option in urban settings. However, if the existing underground infrastructure is not accurately mapped or detected, there is a risk that the new line will intersect with existing utilities, resulting in a cross bore.

Mitigating Cross Bores

The mitigation of cross bores involves a combination of preventive measures and corrective actions:

Pre-Construction Utility Locating and Mapping

Before any trenchless construction begins, it is crucial to conduct thorough locating and mapping of the existing underground utilities. This can involve the use of ground-penetrating radar (GPR), electromagnetic (EM) locators, and other technologies to detect and document the location of existing lines.

Cross Bore Safety Programs

Utility companies and contractors should implement comprehensive cross bore safety programs that include best practices for planning, construction, and post-installation inspections. These programs are designed to prevent cross bores and ensure that any that do occur are quickly identified and addressed.

Coordination and Communication

Effective coordination and communication among utility providers, contractors, and regulatory agencies are essential to ensure that all parties are aware of the potential risks and are working together to mitigate them.

The Role of Sewer Line Inspections

Sewer line inspections, particularly through the use of CCTV-camera-equipped remote controlled sewer scope rovers, play a crucial role in the detection and mitigation of cross bores:

Detection of Cross Bores

Sewer scopes, which involve sending a camera down the sewer line, can provide a visual inspection of the interior of the pipe. This can help identify any signs of a cross bore, such as unusual obstructions or damage to the pipe that might indicate the presence of an intersecting utility line.

Post-Installation Inspections

After the installation of new utility lines using trenchless technology, it is important to conduct sewer line inspections to ensure that no cross bores have occurred. This is a critical step in the prevention of accidents and should be a standard practice in any trenchless construction project.

Maintenance and Monitoring

Regular sewer line inspections can also help in the ongoing monitoring and maintenance of underground infrastructure. By identifying potential issues early, such as small leaks or damage that could lead to a cross bore, proactive measures can be taken to prevent more significant problems.

A GPRS Project Manager lowers a push-fed sewer scope into an open manhole.

GPRS VPI Services Help Mitigate Cross Bore Risk

Cross bores represent a significant challenge in the management of underground utilities, particularly with the increasing use of trenchless technology.

GPRS’ utility locating, utility mapping, and video pipe inspection services provide you and your team members with a comprehensive understanding of the subsurface infrastructure in your project area, so you know where it’s safe to trench or bore, and where breaking ground could have catastrophic consequences.

Our team of over 500 SIM and NASSCO-certified Project Managers (PMs) are strategically stationed across every major market in the U.S., so you always have professional utility locating and mapping, and sewer line inspection services near you.

From skyscrapers to sewer lines, GPRS Intelligently Visualizes The Built World ® to keep you on time, on budget, and safe.

What can we help you visualize? Click below to schedule a service or request a quote today.

Schedule a Service Request a Quote

Frequently Asked Questions

What is a cross bore?

A cross bore is an inadvertent intersection between buried utility lines. A new utility line, installed using trenchless methods like directional boring, intersects and potentially breaches an existing underground utility, such as a sewer line. This can create a pathway for hazardous materials to leak into the sewer system or other utilities.

How are cross bores created?

Cross bores are typically created during the installation of new utility lines using trenchless technology. If existing underground utilities are not accurately mapped or detected, there is a risk that the new line will intersect with these existing lines, resulting in a cross bore.

What are the risks associated with cross bores?

Cross bores can pose significant risks to public safety and the environment. For example, a cross bore involving a gas line and a sewer line can lead to gas leaks into the sewer system, increasing the risk of explosions, fires, and exposure to hazardous gases.

How can cross bores be detected?

Cross bores can be detected through sewer line inspections, particularly using sewer scopes, which involve sending a camera down the sewer line to visually inspect the interior of the pipe. Other detection methods include ground-penetrating radar and electromagnetic locating.

What measures can be taken to prevent cross bores?

Preventing cross bores involves a combination of accurate mapping of existing utilities, thorough pre-construction surveys, the implementation of cross bore safety programs, and post-installation inspections of sewer lines to ensure that no cross bores have occurred.